{"product_id":"25-ft-air-conditioning-copper-hose-hose-extension-1-4-and-1-2-inch-thickened-insulation-cotton-with-nuts-and-other-accessories-fit-for-mini-split-air-conditioner","title":"25 FT Air Conditioning Copper Hose Hose Extension, 1\/4 and 1\/2 Inch Thickened Insulation Cotton with Nuts and Other Accessories Fit for Mini Split Air Conditioner","description":"\u003ch3 data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eKey Features\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"2\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,0,0\" id=\"p-rc_ea13e8a9caa84a16-31\"\u003e\u003cb data-path-to-node=\"2,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty Leak-Proof Copper:\u003c\/b\u003e\u003cspan class=\"citation-17 citation-end-17\"\u003e The core tubing is manufactured from thickened, high-grade copper designed to resist corrosion, cracking, and high-pressure stress.\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e Paired with structural brass nuts that offer extreme hardness, it ensures a reliable, leak-free mechanical joint. \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,1,0\"\u003e\u003cb data-path-to-node=\"2,1,0\" data-index-in-node=\"0\"\u003eAdvanced Thermal Insulation:\u003c\/b\u003e Pre-sheathed in extra-thick, anti-aging insulation cotton that provides excellent thermal retention and shock absorption. \u003ci data-path-to-node=\"2,1,0\" data-index-in-node=\"151\"\u003e(Note: The insulation layer is designed to withstand operating temperatures up to 80°C \/ 176°F).\u003c\/i\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,2,0\"\u003e\u003cb data-path-to-node=\"2,2,0\" data-index-in-node=\"0\"\u003eToolless Parallel Bundling:\u003c\/b\u003e Both the low-pressure (suction) and high-pressure (liquid) lines can be routed cleanly together. The pre-fabricated design eliminates the need for manual on-site welding, fitting perfectly into systems requiring 1\/4\" and 1\/2\" port configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,3,0\" id=\"p-rc_ea13e8a9caa84a16-32\"\u003e\u003cb data-path-to-node=\"2,3,0\" data-index-in-node=\"0\"\u003eComplete Installation Bundle:\u003c\/b\u003e\u003cspan class=\"citation-16 citation-end-16\"\u003e Includes all essential wall finishing accessories, a flexible drain line, and structural electrical cabling to streamline your installation workflow from the outdoor condenser to the indoor air handler.\u003csup class=\"superscript\" data-turn-source-index=\"2\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"4\"\u003e\u003cb data-path-to-node=\"4\" data-index-in-node=\"0\"\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch3 data-path-to-node=\"4\"\u003e\u003cb data-path-to-node=\"4\" data-index-in-node=\"0\"\u003eFitment \u0026amp; Compatibility Guide\u003c\/b\u003e\u003c\/h3\u003e\n\u003cblockquote data-path-to-node=\"5\"\u003e\n\u003cp data-path-to-node=\"5,0\"\u003e\u003cb data-path-to-node=\"5,0\" data-index-in-node=\"3\"\u003ePre-Purchase Notice:\u003c\/b\u003e Please cross-reference your mini-split air conditioner or heat pump manual to confirm that the system’s service ports require 1\/4-inch and 1\/2-inch line sizing.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch4 data-path-to-node=\"6\"\u003e\u003cb data-path-to-node=\"6\" data-index-in-node=\"0\"\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003ch4 data-path-to-node=\"6\"\u003e\u003cb data-path-to-node=\"6\" data-index-in-node=\"0\"\u003eOfficial Kit Component Specifications\u003c\/b\u003e\u003c\/h4\u003e\n\u003ctable data-path-to-node=\"7\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Components\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Length \/ Dimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector \/ Line Sizing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,1,0,0\"\u003e\u003cb data-path-to-node=\"7,1,0,0\" data-index-in-node=\"0\"\u003eCopper Tubing Hose Extension\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,1,1,0\"\u003e25 Feet (approx. 7.6 meters)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,1,2,0\"\u003e\u003cb data-path-to-node=\"7,1,2,0\" data-index-in-node=\"0\"\u003e1\/4 Inch\u003c\/b\u003e (Liquid) \u0026amp; \u003cb data-path-to-node=\"7,1,2,0\" data-index-in-node=\"20\"\u003e1\/2 Inch\u003c\/b\u003e (Suction)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,1,3,0\"\u003eDual-Line Refrigerant Transfer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,2,0,0\"\u003e\u003cb data-path-to-node=\"7,2,0,0\" data-index-in-node=\"0\"\u003eFlexible Condensate Drain Hose\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,2,1,0\"\u003e~5.58 Feet (1.7 meters)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,2,2,0\"\u003eStandard Utility Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,2,3,0\"\u003eWastewater Removal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,3,0,0\"\u003e\u003cb data-path-to-node=\"7,3,0,0\" data-index-in-node=\"0\"\u003eInterconnecting Electrical Cable\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,3,1,0\"\u003e25 Feet (approx. 7.6 meters)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,3,2,0\"\u003eHeavy-Duty Multi-Core\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,3,3,0\"\u003eSystem Power \u0026amp; Signal Control\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch3 data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003eProduct Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003ePart Type:\u003c\/b\u003e Full-Assembly Ductless Mini-Split Line Set \u0026amp; Installation Kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eTubing Material:\u003c\/b\u003e Thickened Refrigeration-Grade Copper \u0026amp; Brass\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eInsulation Material:\u003c\/b\u003e High-Density Shock-Absorbing Thermal Cotton\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eMaximum Insulation Temperature:\u003c\/b\u003e 80°C (176°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-path-to-node=\"10,4,0\" data-index-in-node=\"0\"\u003eCondition:\u003c\/b\u003e 100% Brand New\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch3 data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003ePackage Includes\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003e1 × 25FT Insulated Copper Tubing Assembly\u003c\/b\u003e (1\/4\" \u0026amp; 1\/2\" Lines)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003e1 × 5.58FT Flexible Condensate Drain Hose\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003e1 × 25FT Interconnecting Electrical Cable\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003e2 × Non-Adhesive Decorative Wrapping Tapes\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,4,0\"\u003e\u003cb data-path-to-node=\"13,4,0\" data-index-in-node=\"0\"\u003e2 × Structural Wall Filler Putty Blocks\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,5,0\"\u003e\u003cb data-path-to-node=\"13,5,0\" data-index-in-node=\"0\"\u003e2 × Decorative Wall Caps\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,6,0\"\u003e\u003cb data-path-to-node=\"13,6,0\" data-index-in-node=\"0\"\u003e1 × Protective Wall Sleeve Cylinder\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"15\"\u003e\u003cb data-path-to-node=\"15\" data-index-in-node=\"0\"\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch3 data-path-to-node=\"15\"\u003e\u003cb data-path-to-node=\"15\" data-index-in-node=\"0\"\u003eImportant Mechanical \u0026amp; Installation Notes\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003e\u003cb data-path-to-node=\"16,0,0\" data-index-in-node=\"0\"\u003eProfessional HVAC Certification Advised:\u003c\/b\u003e Working with high-pressure refrigerant lines, performing decay vacuum hold tests, and making main electrical connections involves strict environmental and regional electrical codes. Professional installation by a licensed HVAC technician is highly recommended.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003e\u003cb data-path-to-node=\"16,1,0\" data-index-in-node=\"0\"\u003eManage Line Bends Carefully:\u003c\/b\u003e When uncoiling and routing the 25-foot line set through wall passages, maintain a gradual bending radius. Avoid sharp, abrupt turns to prevent crimping the copper core, which restricts refrigerant flow and strains the compressor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003e\u003cb data-path-to-node=\"16,2,0\" data-index-in-node=\"0\"\u003eSeal Structural Penetrations:\u003c\/b\u003e Utilize the provided wall sleeve cylinder, filler putty, and decorative caps to completely seal the exterior wall opening. This prevents moisture infiltration, pests, and draft leaks from entering the building envelope.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Labworkauto","offers":[{"title":"Default Title","offer_id":48961743945987,"sku":"F8-027673","price":114.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0356\/2589\/4024\/files\/39_3f94948e-4277-4806-9bd3-2ca1f6646424.jpg?v=1782784028","url":"https:\/\/labworkauto.com\/products\/25-ft-air-conditioning-copper-hose-hose-extension-1-4-and-1-2-inch-thickened-insulation-cotton-with-nuts-and-other-accessories-fit-for-mini-split-air-conditioner","provider":"Labworkauto","version":"1.0","type":"link"}